General Specification
♦ 18 Watts AC-DC switching interchangeable power adapter
♦ 5V to 30V,0.01A to 4A output
♦ Energy Efficiency Level VI(85% Min,At 115/230Vac)
♦ Over-load and short circuitprotection,100% burn-in test
♦ 3 years lifetime warranty
♦ Safety certificates:
Electrical Specification
♦
Input
Characteristic |
Minimum |
Norminal |
Maximum |
Unit |
Notes |
Input Voltage |
90 |
100-240 |
264 |
VAC |
|
Input Current |
0.5Amps Max. below norminal input voltage and DC output |
|
|
|
|
A |
|
Input Frequency |
47 |
50~60 |
63 |
Hz |
|
Inrush Current |
No damage shall be occurred and the input fuse shall not be blown up. Cold start at 240VAC input, with rated load and 25℃ ambient |
Earth Leakage Current |
|
|
250 |
μA |
264VAC,50~60Hz |
♦
Output
Characteristic |
Minimum |
Norminal |
Maximum |
Unit |
Notes |
Output Voltage |
5 |
|
30 |
VDC |
|
Load Regulation |
|
|
±5 |
% |
|
Line Regulation |
|
|
±2 |
% |
|
Start Up Delay |
|
|
3 |
S |
115VAC |
Rise Time |
|
|
40 |
mS |
115VAC |
Hold up time |
|
|
5 |
mS |
115VAC |
Overshoot |
|
|
15 |
% |
at Turn on/Turn off |
Overload Protection |
|
|
160 |
% |
auto recover |
Short -circuit Protection |
|
|
|
|
auto recover |
Thermal Protection |
|
|
|
|
auto recover |
Ripple and Noise |
|
|
150 |
mV p-p |
|
Note: At 115/230VAC 25℃ input and output Min. and Max. Load, the ripple and noise are as above when measure with Max. Bandwidth of 20 MHz and parallel 47uF/0.1uF, crossed connected at testing point. |
Environmental Requirements
Characteristic |
Minimum |
Norminal |
Maximum |
Unit |
Notes |
Operating Temperature |
0 |
|
40 |
℃ |
|
Storage Temperature |
-20 |
|
60 |
℃ |
|
Humidity |
5 |
|
90 |
%RH |
operating,non-condensing |
Dropping Packed |
|
|
|
|
|
|
|
|
|
Drop the height is 1000mm. |
|
|
|
|
|
|
|
|
The horizontal surface Consists of hardwood at least 13mm thick, mounted on two layers of |
|
plywood each 19mm to 20mm thick, all supported on a concrete or equivalent non-resilient floor. |
|
|
|
|
|
|
|
|
Vibration |
|
|
|
|
|
|
|
|
|
Operating: IEC 721-3-3 3M3 |
|
|
|
|
|
|
|
|
5-9Hz, A=1.5mm |
|
|
|
|
|
|
|
|
|
(9-200Hz, Acceleration 5m/S2) |
|
|
|
|
|
|
|
|
Transportation: IEC 721-3-2 2M2 |
|
|
|
|
|
|
|
5-9Hz, A=3.5mm |
|
|
|
|
|
|
|
|
|
9-200Hz, Acceleration = 5m/S2 |
|
|
|
|
|
|
|
200-500Hz, Acceleration = 15m/S2 |
|
|
|
|
|
|
|
Axes, 10 cycles per axis |
|
|
|
|
|
|
|
|
No permanent damage may occur during testing. |
|
|
|
|
|
The SAMPLE has to restore to its original situation after power off/on… |
|
|
|
Safety & EMC Requirements
Dielectric Strength Hi-Pot:
Primary to secondary: 4242VDC/5mA/60S for type test.
Insulation Resistance:
Primary to secondary: 20MΩ Min at 500VDC.
EMI Standard
Meet the limits of:
♦ FCC part115 class B rules
♦ EN55022 class B rules
♦ GB9254-1998, GB17625.1-2003
♦ AS/NZS CISPR22:2006